Diabetes Metab Syndr ; 15(1): 243-247, 2021.
Article in English | MEDLINE | ID: covidwho-1065022

ABSTRACT

BACKGROUND AND AIMS: In Colombia, the government established mandatory isolation after the first case of COVID-19 was reported. As a diabetes care center specialized in technology, we developed a virtual training program for patients with type 1 diabetes (T1D) who were upgrading to hybrid closed loop (HCL) system. The aim of this study is to describe the efficacy and safety outcomes of the virtual training program. METHOD: ology: A prospective observational cohort study was performed, including patients with diagnosis of T1D previously treated with multiple doses of insulin (MDI) or sensor augmented pump therapy (SAP) who were updating to HCL system, from March to July 2020. Virtual training and follow-up were done through the Zoom video conferencing application and Medtronic Carelink System version 3.1 software. CGM data were analyzed to compare the time in range (TIR), time below range (TBR) and glycemic variability, during the first two weeks corresponding to manual mode with the final two weeks of follow-up in automatic mode. RESULTS: 91 patients were included. Mean TIR achieved with manual mode was 77.3 ± 11.3, increasing to 81.6% ± 7.6 (p < 0.001) after two weeks of auto mode use. A significant reduction in TBR <70 mg/dL (2,7% ± 2,28 vs 1,83% ± 1,67, p < 0,001) and in glycemic variability (% coefficient of variation 32.4 vs 29.7, p < 0.001) was evident, independently of baseline therapy. CONCLUSION: HCL systems allows T1D patients to improve TIR, TBR and glycemic variability independently of previous treatment. Virtual training can be used during situations that limit the access of patients to follow-up centers.


Subject(s)
COVID-19/epidemiology , Diabetes Mellitus, Type 1/epidemiology , Diabetes Mellitus, Type 1/therapy , Insulin Infusion Systems , Patient Education as Topic/methods , Telemedicine/methods , Adolescent , Adult , Aged , Blood Glucose Self-Monitoring/methods , COVID-19/prevention & control , Cohort Studies , Colombia/epidemiology , Female , Follow-Up Studies , Humans , Hypoglycemic Agents/administration & dosage , Male , Middle Aged , Prospective Studies , Young Adult
2.
Acta Diabetol ; 58(3): 383-388, 2021 Mar.
Article in English | MEDLINE | ID: covidwho-893283

ABSTRACT

AIMS: Spain has been one of the worst affected countries by the COVID-19 pandemic. A very strict lockdown at home was imposed with a tough restriction of mobility. We aimed to evaluate the impact of this exceptional scenario on glucose profile of patients with type 1 diabetes (T1D) prone to hypoglycaemia using sensor-augmented pump (SAP). METHODS: Patients with T1D prone to hypoglycaemia using SAP (640G Medtronic-Minimed®) for at least 6 months under the funding of a National Health Service were included in an observational, retrospective study. Data were collected in two periods: pre-lockdown (PL), February 23rd-March 7th and within lockdown (WL), April 1st to 14th 2020. The primary outcome was the difference in the proportion of time in target glucose range of 70-180 mg/dL (TIR). Additional glucometric data and total daily insulin were also analysed. RESULTS: Fifty-nine patients were included: 33 women, age 46.17 ± 13.0 years and disease duration of 30.2 ± 12.0 years. TIR 70-180 mg/dL (67.6 ± 11.8 vs. 69.8 ± 12.0%), time > 180 (28.1 ± 13.6 vs. 25.5 ± 13.1%), time > 250 (6.9 ± 6.1 vs. 5.1 ± 4.8) and estimated HbA1c (6.94 ± 0.8 vs. 6.75 ± 0.7%) significantly improved (PL vs. WL, respectively, p < 0.05). Time in hypoglycaemia, coefficient of variation, sensor usage and total daily insulin dose remained unchanged. CONCLUSIONS: Lockdown conditions imposed by the COVID-19 pandemic may be managed successfully in terms of glycaemia control by population with DT1 prone to hypoglycaemia using SAP. The strict daily routine at home could probably explain the improvement in the time in glycemic target without increasing the time hypoglycaemia.


Subject(s)
COVID-19 , Diabetes Mellitus, Type 1/drug therapy , Glycemic Control/methods , Hypoglycemia/blood , Insulin Infusion Systems , Pandemics , Quarantine , Adult , Aged , Blood Glucose/analysis , Diabetes Mellitus, Type 1/blood , Female , Humans , Hypoglycemic Agents/administration & dosage , Hypoglycemic Agents/therapeutic use , Insulin/administration & dosage , Insulin/therapeutic use , Male , Middle Aged , Retrospective Studies , Treatment Outcome
3.
J Clin Res Pediatr Endocrinol ; 13(4): 468-472, 2021 11 25.
Article in English | MEDLINE | ID: covidwho-883950

ABSTRACT

The current Coronavirus disease-2019 (COVID-19) pandemic has forced health care teams to look for alternative approaches to manage a great number of children with diabetes, not only in rural but also in urban locations. The aim was to assess the provision of information about follow-up of new-onset pediatric type 1 diabetes (T1D) patients, and to investigate the integration of telemedicine into routine clinical care in the long term. The changes in coefficient of variation (CV), standard deviation and percentages of time in range (TIR), time below range (TBR) and time above range were evaluated in eight children with new-onset T1D, diagnosed during the COVID-19 pandemic. The study period was two-months of follow-up using a telemedicine system. Median follow-up time was 51 (24-66) days. Two of the patients were using low glucose suspend system and six were on multiple daily injection therapy. Target TIR values were achieved in seven patients in the last televisit and, in line with recent guidelines, a TBR <70 mg/dL (<3.9 mmol/L) (level 1 hypoglycemia) of <4% and a TBR <54 mg/dL (<3.0 mmol/L) (level 2 hypoglycemia) of <1% were achieved in all patients. Seven patients achieved a CV of <36% at their last televisit. Telemedicine as an alternative follow-up tool during unusual circumstances such pandemics, even in countries where it is not routinely used, could be beneficial to achieve optimum glycemic control in patients with new-onset T1D.


Subject(s)
COVID-19/epidemiology , Diabetes Mellitus, Type 1/therapy , Monitoring, Physiologic/methods , Telemedicine , Adolescent , Blood Glucose/drug effects , Blood Glucose/metabolism , Blood Glucose Self-Monitoring/instrumentation , Blood Glucose Self-Monitoring/methods , Child , Child, Preschool , Diabetes Mellitus, Type 1/blood , Diabetes Mellitus, Type 1/diagnosis , Diabetes Mellitus, Type 1/drug therapy , Female , Follow-Up Studies , Humans , Insulin/administration & dosage , Insulin Infusion Systems , Male , Pandemics , SARS-CoV-2 , Smartphone , Treatment Outcome , Turkey/epidemiology